HANGZHOU ZION COMMUNICATION CO., LTD

Our Purpose To provide better signal transmission products and solutions in the world. Our Mission Focusing on customer needs, we provide customers with more competitive signal transmission products,

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Fire Resistant Cable /

FRLR 16AWG Shielded Fire Alarm Cable 4 Cores Solid Copper for Fire Monitoring

Contact Now
HANGZHOU ZION COMMUNICATION CO., LTD
Visit Website
City:hangzhou
Province/State:zhejiang
Country/Region:china
Contact Person:MrJames
Contact Now

FRLR 16AWG Shielded Fire Alarm Cable 4 Cores Solid Copper for Fire Monitoring

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :Zion communication OR OEM
Certification :ISO, CE, RoHS, UL
Model Number :Fire Alarm Cable 16AWG FPLR
MOQ :20 KM
Packaging Details :500FT, 1000FT, Wooden Spool, Carton
Delivery Time :25 working days
Payment Terms :T/T, L/C
Supply Ability :1000KM / Month
Conductor :Solid Bare Copper
Insulation :Riser-Rated PVC
Shield :Aluminum / Mylar
Jacket :Riser-Rated PVC
Color :Red
Package :500FT, 1000FT, Wooden Spool, Carton
more
Contact Now

Add to Cart

Find Similar Videos
Black Color CAT6 Network Cable PE Jacket For Outdoor Networking , High Performance 00:40
Black Color CAT6 Network Cable PE Jacket For Outdoor Networking , High Performance
Self-supporting Bow-type Steel Strength Member FTTH Drop Cable GJYXCH 00:39
Self-supporting Bow-type Steel Strength Member FTTH Drop Cable GJYXCH
Fiber Fast Connector - LC / SC / FC - Fiber Optic Cable Assemblies from China manufacturer - Zion Communication 01:01
Fiber Fast Connector - LC / SC / FC - Fiber Optic Cable Assemblies from China manufacturer - Zion Communication
UTP CAT5E RJ45 180 Degree Keystone Jack For Network 01:05
UTP CAT5E RJ45 180 Degree Keystone Jack For Network
LC SX 0.9mm Pre-polished Ferrule Field Assembly Fiber Optical patch Connector 01:25
LC SX 0.9mm Pre-polished Ferrule Field Assembly Fiber Optical patch Connector
All Dielectric Self-supporting Aerial Cable ADSS With PE  or AT Outer Sheath 01:27
All Dielectric Self-supporting Aerial Cable ADSS With PE or AT Outer Sheath
1X2 CWDM Device(3 Ports) 00:48
1X2 CWDM Device(3 Ports)
GYFTA53 Double Sheathed Fiber Optic Cable for Directly Underground Application 01:14
GYFTA53 Double Sheathed Fiber Optic Cable for Directly Underground Application
Fiber Optic Vertical/Horizontal Splice Closure Black/White 00:41
Fiber Optic Vertical/Horizontal Splice Closure Black/White
12 Fibers MTP Female To MTP Female Patch Cord Singlemode 3.0mm LSZH 01:29
12 Fibers MTP Female To MTP Female Patch Cord Singlemode 3.0mm LSZH
View Product Description

FRLR 16AWG Shielded Fire Alarm Cable 4 Cores Solid Copper for Fire Monitoring

Quick Details

  • Fire Alarm Cable
  • FPLR 16AWG 4 Cores
  • Solid Bare Copper Conductor
  • Unshielded types: 2C / 4C
  • Shielded types: 2C / 4C
  • RISER-Rated PVC Insulation
  • RISER-Rated PVC Jacket
  • 500FT, 1000FT, Wooden Spool, Carton
  • Power Limited Fire Alarm System
  • MOQ: 20 KM

Description

Zion communication ELECTRONICS is the leading manufacturer of fire alarm system cables for the fire protection industry. Our innovative product line includes all power-limited cables for use in the NEC Article 760.
NATIONAL ELECTRIC CODE (NEC) ARTICLE 760: NEC Article 760 covers the installation of wiring and equipment of fire alarm systems,including all circutis controlled and powered by the fire alarm system.
These systems are defined in the NEC as " The portion of wiring system between the load side of the overcurrent devices or the power-limited supply and the connected equipment of all circuits powered
and controlled by the fire alarm system."
Type FPLR- FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run
in a shaft or from floor to floor.All FPLR cables are listed as having fire-resistantcharacteristics capable of preventing fire from traveling from floor to floor.Riser cables must pass both UL test 1424
and the Vertical riser test UL 1666.
KT1423 Fire Alarm Cables 16AWG FPLR-CL2R PVC Insulation Riser-Rated PVC Jacket
Application
Indoor for:
Audio Circuits
Control Circuits
Initiating Circuits
Notification Circuits
Properties
Temperature Rating: '-20 to 75℃
Operating Voltage: 300 Volts max.
Flame Rating: UL 1666(Riser),C(UL)FT4
Insulation & Jacket: PVC
Shielded types
Conductors NOM.THICKNESS(MM) Nominal0.D. Capacitance Impedance DC Resistance
Number Solid Insulation Jacket Inch pf/ft Ohms Ohms/M'
2 16 AWG 0.008" 0.015" 0.166" 46 34 4.1
4 16 AWG 0.008" 0.015" 0.195" 46 34 4.1
Drain Wire 20 AWG Solid Tinned-Copper
Shield 0.001" thick Aluminum/Mylar
Color
Number Description
2 Blk,Red
4 Blk,Red,Ylw,Grn
Order Informations:
Print

Zion communication KT1423 ×C14 E×××××××(UL) FPLR

OR CL2R SUN RES(ROHS) ××××FT
DEVICE/ZONE A B C D E F 1 2 3 4 5 6 7 8 9

Packing 500FT, 1000FT, Wooden Spool, Carton, Pallet

Competitive Advantage:

1, From raw materials to final products, we perform intense quality checks to maintain our product quality:

A, Incoming material inspected by QC.

B, Manufacturing Process Control

C: Workers trained daily/weekly/monthly

D: Work instructions manual at each work station

E: 5S system implemented

F: Machine maintenance procedure

G: Quality Control and Final Inspection

The QC staff will check the material, process product

and final product according to the specification or test procedure.

2, Our R&D efforts center on reinforcing and developing element technologies

needed to support the future growth and success for customers and Zion communication.

3, We know customers have urgent needs.

We are skilled at effective communication to interact with customers.

In order to provide prompt service, we can answer for you 7*24 hours.

4, We can Quickly and professionally answer for the inquire

5, More than 1000 kinds of cable, connectors and assembles can be produce and organized from us

6, Intime delivery

FRLR 16AWG Shielded Fire Alarm Cable 4 Cores Solid Copper for Fire Monitoring

Inquiry Cart 0
You May Like
4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System
4 Core 1.00mm2 Shielded FRLS Fire Resistant Cable for Installation in Fire System
FRLS 2 Core Shielded 0.75mm2 Fire Resistant Cable Low Smoke PVC Jacket
FRLS 2 Core Shielded 0.75mm2 Fire Resistant Cable Low Smoke PVC Jacket
FRHF 4 Core Unshielded 0.22mm2 Fire Resistant Cable Halogen Free PVC Jacket
FRHF 4 Core Unshielded 0.22mm2 Fire Resistant Cable Halogen Free PVC Jacket
FRHF 2 Core 0.50mm2 Fire Resistant Cable Copper Conductor with Silicone Insulation
FRHF 2 Core 0.50mm2 Fire Resistant Cable Copper Conductor with Silicone Insulation
PH120 SR 114E Enhanced Fire Resistant Cable BS EN 50200 Standard for Emergency
PH120 SR 114E Enhanced Fire Resistant Cable BS EN 50200 Standard for Emergency
FRLS 2 Core Unshielded 1.00mm2 Fire Resistant Cable for Connecting Fire Alarms
FRLS 2 Core Unshielded 1.00mm2 Fire Resistant Cable for Connecting Fire Alarms
Silicone Insulation Fire Resistant Cable FRLS Standard Unshielded 0.22mm2
Silicone Insulation Fire Resistant Cable FRLS Standard Unshielded 0.22mm2
Unshielded 0.50mm2 Fire Resistant Cable Bare Copper Conductor with FRLS Jacket
Unshielded 0.50mm2 Fire Resistant Cable Bare Copper Conductor with FRLS Jacket
PH30 SR 114H Standard Fire Resistant Cable FR-LSZH for Fire Detection Circuits
PH30 SR 114H Standard Fire Resistant Cable FR-LSZH for Fire Detection Circuits
Low Smoke PVC Jacket Fire Resistance Cable Unshielded 4 Core 0.75mm2 FRLS Level
Low Smoke PVC Jacket Fire Resistance Cable Unshielded 4 Core 0.75mm2 FRLS Level
12AWG Shielded FPLR-CL2R Fire Alarm Cable Riser-Rated PVC for Control Circuits
12AWG Shielded FPLR-CL2R Fire Alarm Cable Riser-Rated PVC for Control Circuits
Plenum-Rated Fire Alarm Cable 12AWG 2C Solid Copper for Fire Protective Circuits
Plenum-Rated Fire Alarm Cable 12AWG 2C Solid Copper for Fire Protective Circuits
16AWG 4 Cores Solid Shielded FPLP  Fire Alarm Cable Plenum-Rated PVC Jacket
16AWG 4 Cores Solid Shielded FPLP Fire Alarm Cable Plenum-Rated PVC Jacket
Riser-Rated Fire Alarm Cable 14AWG 2 Conductors Solid Copper for Security System
Riser-Rated Fire Alarm Cable 14AWG 2 Conductors Solid Copper for Security System
16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC
16AWG 4 Core Fire Alarm Cable Solid Bare Copper Conductor with Non-Penum PVC
Send your message to this supplier
*From:
*To:

HANGZHOU ZION COMMUNICATION CO., LTD

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now