Add to Cart
1/2” Radiating Leaky Cable(H Band) NO.7101131 | ||||||||
CABLE TYPE: RFXT 1/2”-50H(BHF);HLRCAY(Z)-50-12H | ||||||||
Construction | ||||||||
Inner Conductor | copper tube | Ø 4.8 mm | ||||||
Dielectric | Cellular polyethylene | Ø 12.2 mm | ||||||
Outer Conductor | Copper foil | Ø 13.2 mm | ||||||
Jacket | Black PE or Black LSZH | Ø 15.8 mm | ||||||
Marking | Brand, cable type, cable ID, meter mark | |||||||
Electrical Characteristics at +20℃ | ||||||||
Characteristic impedance | 50 ± 2 Ω | ![]() | ||||||
Velocity | 0.88 | |||||||
Capacitance | 76 pF/m | |||||||
Insulation Resistantce | >5000 MΩ.km | |||||||
Insulation Voltage | 6000 V | |||||||
Jacket Spark Test Voltage | 8000 V | |||||||
VSWR | ||||||||
Frequency (MHz) | VSWR (Max) | |||||||
790~960 | 1.30 | |||||||
1700~1900 | ||||||||
1900~2025 | 1.40 | |||||||
2100~2200 | ||||||||
2300~2500 | ||||||||
2500~2700 | ||||||||
MECHANICAL CHARACTERISTICS | ||||||||
Weigh | 210kg/km | |||||||
Maximum pulling force | 1000N | |||||||
Minimum bending radius | ||||||||
Single bending | 125 mm | |||||||
Repeated bending | 350 mm | |||||||
Operating temperature range | -40~ +80℃ | |||||||
Min. installation temperature | -20℃ (PE); -5℃ (LSZH) | |||||||
Attenuation and Coupling Loss | ||||||||
Frequency (MHZ) | Attenuation dB/100m @20℃ | Coupling Loss (50%/95%) dB | ||||||
800 | 7.3 | 79/84 | ||||||
900 | 7.9 | 76/82 | ||||||
1800 | 14.3 | 67/70 | ||||||
1900 | 15.0 | 67/71 | ||||||
2000 | 15.7 | 68/72 | ||||||
2200 | 16.7 | 67/71 | ||||||
2400 | 17.6 | 67/72 | ||||||
2600 | 18.6 | 65/69 | ||||||
2700 | 18.9 | 66/70 | ||||||
Note: Attenuation tolerance 5%; Coupling Loss tolerance ±5dB | ||||||||
Order Informations: | ||||||||
Marking | HELLOSIGNAL 1/2” Radiating Leaky Cable(H Band) ××× M | |||||||
Package | Inquired Length on Wooden Drum and Pallet. | |||||||
Brand | HELLOSIGNAL® OR OEM |