1 1/4”Radiating Leaky Cable(H Band) NO.7101134 | ||||||||
CABLE TYPE: RFXT 1 1/4”-50H(BHF);HLRCTCY(Z)-50-32H | ||||||||
Construction | ||||||||
Inner Conductor | copper tube | Ø 13.1 mm | ||||||
Dielectric | Cellular polyethylene | Ø 33.0 mm | ||||||
Outer Conductor | Copper foil | Ø 34.0 mm | ||||||
Jacket | Black PE or Black LSZH | Ø 37.5 mm | ||||||
Marking | Brand, cable type, cable ID, meter mark | |||||||
Electrical Characteristics at +20℃ | ||||||||
Characteristic impedance | 50 ± 2 Ω | ![]() | ||||||
Velocity | 0.88 | |||||||
Capacitance | 76 pF/m | |||||||
Insulation Resistantce | >5000 MΩ.km | |||||||
Insulation Voltage | 10000 V | |||||||
Jacket Spark Test Voltage | 10000 V | |||||||
VSWR | ||||||||
Frequency (MHz) | VSWR (Max) | |||||||
790~960 | 1.30 | |||||||
1700~1900 | ||||||||
1920~2025 | 1.40 | |||||||
2110~2200 | ||||||||
2300~2500 | ||||||||
2560~2620 | ||||||||
MECHANICAL CHARACTERISTICS | ||||||||
Weigh | 780kg/km | |||||||
Maximum pulling force | 2000N | |||||||
Minimum bending radius | ||||||||
Single bending | 400 mm | |||||||
Repeated bending | 500 mm | |||||||
Operating temperature range | -40~ +80℃ | |||||||
Min. installation temperature | -20℃ (PE); -5℃ (LSZH) | |||||||
Attenuation and Coupling Loss | ||||||||
Frequency (MHZ) | Attenuation dB/100m @20℃ | Coupling Loss (50%/95%) dB | ||||||
700 | 2.3 | 76/82 | ||||||
800 | 2.7 | 71/78 | ||||||
900 | 3.1 | 69/73 | ||||||
960 | 3.2 | 65/68 | ||||||
1800 | 5.0 | 66/72 | ||||||
1900 | 5.6 | 62/68 | ||||||
2000 | 5.8 | 67/72 | ||||||
2200 | 6.2 | 66/72 | ||||||
2400 | 7.8 | 64/71 | ||||||
2600 | 8.0 | 69/76 | ||||||
2620 | 8.3 | 68/76 | ||||||
Note: Attenuation tolerance 5%; Coupling Loss tolerance ±5dB | ||||||||